NIM-Eclipse Spinal System Software Update History
NIM-Eclipse Ver. 3.2.325 System full version. Released 3/22/2010
NIM-Eclipse Ver. 3.2.325 Reader full version. Released 3/22/2010
Key New Features, Changes and Fixes
Neurophysiologist Supported System:
- Added Nerve Proximity stimulation mode.
- Windows 7 compatibility.
- Live IOM remote monitoring (3 second delay).
- Added NIOM Explorer VPN browser providing status and control of all monitoring systems on the network.
- Added chat window when remote monitoring is implemented via Shared Folder.
- Added 5 s/div EMG timebase.
- Added Low Electrical Stim beep tone to indicate when measured current is first detected confirming tissue contact.
- Added ability to swap Active and Reference electrode columns in channel table.
- Improved sound quality of EMG and SigTrig tones.
- Unique EMG tones can be used to discern left and right EMG trace activity.
- Last Average acquisition time is now displayed during Runtime.
- Fixed mouse wheel interface when using the stimulus intensity entry field.
- Improved manual Set switching speed.
- Fast rebuild of EP traces in review.
- Added support for Invos 5100C Cerebral Oximeter.
- Modified factory support via the Internet.
Surgeon Directed System:
- Modified Train of Four and Nerve Proximity settings.
- Case information is now included in the Summary report.
- Display first pedicle response current next to Level buttons when "Stop after first response" is not selected.
- Nerve Root Level buttons now displayed with gray color when no response is found.
- Modified factory support via the Internet.
Patch History
3.0.303
Neurophysiologist Supported System:
- Fixed saving screen snapshots. (Problem introduced in ver. 3.0.302)
3.0.302
Neurophysiologist Supported System:
- Added support for laptop computer built-in cameras.
- Fixed potential hang when the Print button is clicked and memory resources are low.
Surgeon Directed System:
- EMG Signal Triggered responses above threshold (Events) are saved when free-run EMG is displayed.
- Response Start default value for new tests was changed from 4 ms to 8 ms.
- Displayed text message was modified when TOF calibration fails.
- Fixed displayed Event marks in the patient data review Move To Bar.
- Fixed potential hang when the Print button is clicked and memory resources are low.
- Fixed Help file.
3.0.301
Neurophysiologist Supported System:
- Added auto-reset feature to controller during power dip or communication error.
- Added ability to superimpose trends.
- EMG threshold tone is now based on free run EMG and not Sig Trig trace.
- Fix Sig Trig traces of different sweep lengths in different Sets based on Common Set EMG.
- Fix USB controller/computer communication protocol error.
Surgeon Directed System:
- Added auto-reset feature to controller during power dip or communication error.
- Changed Response Start read only test default value from 4 ms to 8 ms
- Removed beep when changing volume slider.
- Fix USB controller/computer communication protocol error.
- Modified factory support via the Internet.
|