Review the features of the latest software releases for the Eclipse and EpochXP Neurological Workstations.
NIM-Eclipse NS, Eclipse
Software release 3.2.320
Released August 6, 2009, this version provides the following new features and enhancements:
- Settings values can be changed directly in tables - Settings values can be changed from indivudual cells inside the Trace, Trend, Stimulus Sequence and Set Sequence tables
- Report Generator - Quickly create highly customizable, proffessional reports with a minimum of typing using templates,.
- Added Case Information in the "Patient and Case Info" dialog - Case Staff and Case Info fields added. Export patient and case information to a file and email that file as an attachment.
- Selective EP Next Average dialog - Starts a Next Average for selected EP traces only.
- Selective Reset EP Trace dialog - Resets only selected EP traces.
- Selective Baseline install dialog - Install Baselines for selected EP traces.
- Selective Trace ON/OFF dialog - Use this control to quickly switch Traces On or Off.
- Increase stimulation rate when a stimulus is switched off - When a stimulus in the test is not needed, use this feature to increase the stimulus rate for faster EP updates.
- Display a selected portion of the screen on a secondary display monitor - View an arbitrary rectangular area of the display screen on secondary display monitor. Provide the surgeon with a view of the key monitored data.
- Micro Electrode Recording (MER) capability for up to 4 channels - Use the feature to monitor up to four MER channels for spike counting including analysis of spike Rate and Burst Index
- Automatic comments added at start and end of NetOp sessions - Start and end times of NetOp remote monitoring sessions are automatically included in Comments. Duration time is automatically calculated and added to the end comment.
NIM-Eclipse SD
Software release 3.2.320
Released August 6, 2009, this version provides the following new features and enhancements:
- Display of measured current for Pedicle level responses in Screw and N.Root screens - The final value of measured current is displayed next to the level button after a pedicle level test is completed
- Report Generator - Quickly create highly customizable, proffessional reports with a minimum of typing using templates,.
- Simulation Mode - If the controller is not connected when the Surgeon Directed module starts the message box will allow continuation in Simulation mode .
- Display a selected portion of the screen on a secondary display monitor - View an arbitrary rectangular area of the display screen on secondary display monitor. Provide the surgeon with a view of the key monitored data.
- Resume a test - Use this feature to exit the test (to review patient data for example) and then return to the test. The “Resume” button is enabled only when the test to be resumed was started in less then 24 hours.
- Notch filter for EMG traces - Use this feature to remove excessive line-related interference.
- Volume button blink indicator - This feature signals when the audio volume level may be too low.
- Automatic comments added at start and end of NetOp sessions - Start and end times of NetOp remote monitoring sessions are automatically included in Comments. Duration time is automatically calculated and added to the end comment.
EpochXP
Software release 3.0
Released December 2, 2008, this version provides the following new features and enhancements:
- Windows Vista compatibility
- Sweep Length - Sweep length can be changed to any value between 1 ms and 5,000 ms.
- Sweep length can be changed during monitoring.
- Enhanced Summary Report - includes saved screens, EP trace information and marker data.
- View saved screens in the edit comment window. - Quickly move to next or previous comment.
- Added additional patient information fields. - Add employer and insurance information
- Change patient name and ID during monitoring or in Review.
- Install baselines for a single EP Trace Area. - Improved baseline selectivity
- Start a Next Average for a single EP Trace Area. - Improved trace control and selectivity
- Added Timebase control to EP and SigTrig Stacks. - Zoom or contract stack timebase
- Click on a Trended value in Review to display trace data at that time. - Speed data analysis during review
- Select a Vital Signs monitor from the Settings General page during monitoing.
- Display the Numeric EP marker window in Secondary Window. - View key marker information at a glance
- Display the Measured Current window in Review. - View measured current for each trace during review.
- Zoom Secondary window over Parameters notebook. - Display additional numeric information.
- Added copy Window, - Copy the area or the whole screen to the clipboard.
- Added use of extra mouse buttons. - for fast Print Screen and mute audio.
- Change trace display SNS using mouse wheel. - Quickly change parameters using mouse wheel.
- Clear SigTrig EMG traces. - remove previously captured sig trig traces.
|